Gold Member Since 2011
Audited Supplier
INVT Power System (Shenzhen) Co., Ltd.

Online Ups, Single Phase Ups, Tower Ups manufacturer / supplier in China, offering Ht11 1-3kVA Single Phase 0.9pf Online UPS, 3 Phase Modular UPS, Invt Hr 1-10kVA 0.9pf Rak Mount UPS and so on.

(/ )

Supplier Homepage Product HT11 Tower UPS Ht11 1-3kVA Single Phase 0.9pf Online UPS

Ht11 1-3kVA Single Phase 0.9pf Online UPS

FOB Price: Get Latest Price
Min. Order: 1 Set
Production Capacity: 5000sets/Month
Transport Package: Standard Invt Packing
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HT11 Series
  • Type: On-line
  • Output Power Factor: 0.9
  • Power Range: 1-3kVA
  • Specification: 6~20KVA
  • HS Code: 85044020
  • Phase: Single Phase
  • Protection: Overvoltage
  • Output Voltage: 200V/208V/220V/230V/240V
  • Trademark: INVT
  • Origin: China
Product Description
Features:
High frequency and double conversion on-line technology

1.Wide input voltage range,True online UPS
2.Battery cold start .
3.DSP technology,advantaged battery management 
4.Automatical fan speed adjustment .Overload and short circuit protection
5. LCD status display, more information and history log
6.Complete protection functions 
7.Network/Fax/modem surge protections
8.EMI/RFI noise filter
9.Smart Rs232 port with monitoring software 
10. PFC technology
11.Intelligent slot for SNMP adaptor(optional)
 

  HT1101S HT1101L HT1102S HT1102L HT1103S HT1103L
INPUT  
Cold Start YES, default frequency=50Hz or settable
Acceptable Input Voltage 110VAC~288VAC
  100% load@>176VAC
80% load@>154VAC
70% load@>132VAC
50% load@>110VAC
Phase Single phase in,single phase out
Transfer Voltage Range   (200VAC/208VAC/220VAC/230VAC/240VAC)
    -Line low transfer 110VAC
    -Line low recovery 121VAC
    -Line high transfer 288VAC
    -Line high recovery 281VAC
Input Current  
    -Rating(nominal input voltage) 4.8A 9.6A 14.4A
Input Power Factor ≥0.97
Input Frequency Range 40~70Hz
OUTPUT      
Frequency adaptable Settable
Power  
    -Power(kVA) max 1 2 3
    -Power(kW) max 0.9(0.8 for 200VAC/208VAC) 1.8(1.6 for 200VAC/208VAC) 2.7(2.4 for 200VAC/208VAC)
Output Voltage  
    -Waveform(Bat. Mode) Pure Sine Wave
    -Nominal voltage 200/208/220/230/240VAC
    -Voltage regulation ± 1 %
    -Transient response   ≤5% (0% - 100% -0%)
    -Transient recovery ≤10ms (0% - 100% -0%)
    -Voltage distortion ≤1% THD, linear load        
  ≤5.5% THD, non-linear load ≤5% THD, non-linear load ≤5% THD, non-linear load
Output Frequency  
    -Synchronization range ±5Hz default
    -Slew rate 0.5~5Hz/s,2 Hz/s default
    -Battery mode (50±0.1) Hz default
Transfer Time  
    -Line mode to battery mode 0
    -Inverter to bypass 2ms
Efficiency  
    -Line mode with battery full charged 86%@100% load, 87%@50% load 91%@100% load, 88%@50% load 88%@100% load, 90%@50% load
    -ECO mode 94.0% 95.0% 95.0%
    -Battery mode 83%@100% load, 84%@50% load 87%@100% load, 88%@50% load 87%@100% load, 89%@50% load
Noise(1m away) <43dB@<60%load,<47dB@>60%load <45dB@<60%load,<50dB@>60%load <45dB@<60%load,<50dB@>60%load
Overload Capability(Inverter) 105%~130%: Transfer to bypass after 1 mins.
150%: Transfer to bypass after 30s
Overload Capability(Battery Mode) 105%~130%:shutdown after 10s
150%:shutdown after 5s
Overload Capability (Bypass Mode) <130%: Long time
>130%&<150%:Shutdown after 10min
>150%&<180%:Shutdown after 5 seconds
Crest Ratio 3:1
BATTERY  
Rating/Type 12VDC/7Ah Depend on the capacity of external batteries 12VDC/7Ah Depend on the capacity of external batteries 12VDC/7Ah Depend on the capacity of external batteries
Quantity 3 6 8
DC Voltage 36VDC 72VDC 96VDC
Back-up Time 6mins @80% load Depend on the capacity of external batteries 6mins @80% load Depend on the capacity of external batteries 5.5mins @80% load Depend on the capacity of external batteries
Battery-Low Voltage 33VAC~35VDC depending on load 66VDC~70VDC depending on load 88VDC~94VDC depending on load
Charger    
    -Charging voltage float:41VDC/boost:42VDC float:82VDC/boost:84VDC float:109VDC/boost:112VDC
    -Charging current (max) 1A 8A 1A 8A 1A 8A
    -Charging time 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries
Leakage current <1mA <1mA <1mA
INDICATOR & ALARM  
    -Display LED+LCD
    -Alarm two short one long
    -Fault Continuous beeping
INTERFACE  
    -Smart RS232 Standard Cable support INVT Power Monitor Software
    -SNMP(option) Power Managment from SNMP Manager and Web Browser
OPTION  
    -Intelligent Kits DB9 port, dry contact
    -USB B-type USB port
    -SNMP Kits pluggable type
MECHANICAL  
    -W*D*H (mm) 144*353*222 190*374*336 190*426*336
    -W*D*H (mm)(shipment) 240*448*320 285*470*420 285*521*420
    -Net Weight (KG) 12 6 21 10.5 25.6 11.5
    -Package Weight(KG) 13 7 22 12 27 13
Color Black default
Send your message to this supplier
Avatar
Miss Sarah
Marketing
*From:
To: Miss Sarah
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category