Modularized Design Large Power UPS 10KVA-200KVA
System characteristics:
1. Modular design, hot swappable.
2. Strong load adaptability for linear and nonlinear load.
3. Intelligent module and system protection design.
4. Incredible low noise system design.
5. Double DSP controller for individual power module.
6. Digital control for the whole parts including rectifier, inverter, charger and discharger.
7. IGBT modules rather than discrete components are applied in the power module.
8. Inbuilt power distribution for input and output connection.
9. Large touch screen LCD with plenty of information.
10. Independent charger for batteries, intelligent battery management system.
11. Digital paralleling technology, very low circle current between modules.
12. Totally front access, top and bottom cable connection.
13. Each individual module is configured with independent controller, avoid single point failure risk.
| Capacity | 10-200KVA | |||||||||
| Main Input | ||||||||||
| Input voltage | 380V/400V/415V(line to line) | |||||||||
| Input frequency | 50/60Hz | |||||||||
| Power factor | > 0.99 | |||||||||
| Input cuurent THD(Total Harmonic Distortion) | < 3% | |||||||||
| Input voltage window | -40%~+25% | |||||||||
| Frequency window | 40-70HZ | |||||||||
| Battery | ||||||||||
| Battery voltage | ± 240VDC | |||||||||
| Charger power | 20%*Power | |||||||||
| Charger voltage precision | 1% | |||||||||
| Bypass | ||||||||||
| Bypass voltage | 380V/400V/415V, three phase | |||||||||
| Bypass voltage window | -20%-+15%, full load, settable | |||||||||
| Bypass overload capabiltiy | 150%, long time operation | |||||||||
| 180%, shut down after 10 minutes | ||||||||||
| > 180%, shut down after 200ms | ||||||||||
| Output | ||||||||||
| Output voltage | 380V/400V/415V, three phase | |||||||||
| Voltage precision | ± 0.5% (balance load), ± 1% (unbalance load) | |||||||||
| Voltage THD(Total Harmonic Distortion) | THD< 1%(linear load), THD< 3%(nonlinear load) | |||||||||
| Power factor | 0.8 | |||||||||
| Phase tolerance | 120° ± 0.5° (balance and unalance load) | |||||||||
| Crest factor | 3: 1 | |||||||||
| Overload capabiltiy | 110%, transfer to bypass after 1hour | |||||||||
| 125%, transfer to bypass after 10 minutes | ||||||||||
| 150%, transfer to bypass after 1 minute | ||||||||||
| > 150%, transfer to bypass after 200ms | ||||||||||
| System | ||||||||||
| System efficiency | Normal mode: 95% | |||||||||
| ECO mode: 99% | ||||||||||
| Battery mode efficiency | 95% | |||||||||
| Display | LCD+LED, Touch screen and keyboard | |||||||||
| IP class | IP20 | |||||||||
| Interface (Communication Ports ) | RS232, RS485, Dry contacts, SNMP card, EPO, Generator interface | |||||||||
| Installation/Connection | Top or bottom cable connection | |||||||||
| Operation temperature | 0-40C | |||||||||
| Storage temperature | -25~70C | |||||||||
| Relative humidity | 0-95% (non-comdensing) | |||||||||
| Noise(dB) | < 55dB | |||||||||
| Weight(KG) | 6-module cabinet | 150KG | ||||||||
| 10-module cabinet | 180KG | |||||||||
| Module | 10KVA: 20KG | |||||||||
| 15KVA: 21KG | ||||||||||
| 20KVA: 22KG | ||||||||||
| Dimension(W*D*H)(mm) | 6-module cabinet | 600*900*1600 | ||||||||
| 10-module cabinet | 600*900*2000 | |||||||||
| Module | 400*600*133 (10KVA/15KVA/20KVA) | |||||||||
More Product Features
| HS Code: | 85044020 |
|---|---|
| Trademark: | INVT |
| Standard: | 10-200KVA |
| Minimum Order: | 1 Pieces |
| Origin: | China |
| Packing: | Mooden Carton |
| Type: | On-line |
| Protection: | Overvoltage |
| Phase: | Three Phase |
| Output Power Factor: | 0.8/1 |
| Output Voltage: | 380V/400/415 or 200V/208V |
| Export Markets: | South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
| Company: | INVT Power System(Shenzhen) Co., Ltd. |
Most Popular
-

Digital LCD Display Online UPS 1kVA 2kVA 3kVA
LCD display 1000va, 2000va, 3000va Output ... -

UPS - Online Uninterrupted Power Supply
Features: 1; True online double conversion UPS. ... -

Line Interactive UPS with AVR (T8 Series)
T8 series pure sine wave inverter with charger, ...
-

Normal Frequency Online UPS (single phase in and out) ...
Single -phase in and Single-phase out double ... -

Home UPS
Home UPS Our competitive advantage: 1. Use ... -

LCD High Frequency Online UPS Systems with 0.8 Output Power ...
*DSP Technology The application of DSP ...
-

Solar Inverter/Home Use Inverter
High frequency inverter: 1. Output waveform: ... -

Power Inverter 500W with Digital LED Display (MSD Series ...
JYINS MSD series digital inverter combine ... -

Duyd-D -P Series EPS (Off-Line UPS)
Introduction Emergency Power Supply (EPS for ...
-

UPS Offline (500-1200VA) (AT Series)
Key Features and Benefits: 1. Wide input voltage ... -

Modularized Design of Large Power UPS 30KVA-120KVA
* Three phase in three phase out, supports ... -

LCD Home UPS 500-2000va
LCD Home Inverter UPS IG3110C Series 500-2000VA ...
-

UPS Power Pure Sine Wave UPS With Smart RS-232, Snmp Card ...
UPS Power: Pure Sine Wave UPS With Smart RS-232, ... -

Digital Line Interactive UPS 600VA 800VA 1000VA 1500VA
Line inverteractive UPS is a high frequecny UPS. ... -

Rack Mount Online UPS 2--3kVA
1)Concise LED display and comprehensive ...
Quick Products |
Inquiry Basket (