Basic Info
  • Model NO.: HT1106 HT1110 HT1115 HT1120 HT3110 HT3115 HT3120
  • Type: On-line
  • Application: Communication
  • Standby Time: Long-acting Machine
  • Output Capacity: Medium Type
  • Brand: Invt
  • Output Voltage: 200V/208V/220V/230V/240V
  • Trademark: INVT
  • Origin: China
  • Phase: Single Phase
  • Protection: Overvoltage
  • Classification: Lighting/Power
  • Standby UPS: Sine Wave Output UPS
  • Equipment Mode: Centralized Model
  • Output Power Factor: 0.9
  • Power Range: 6~20kVA
  • Specification: 6~20KVA
  • HS Code: 85044020
Product Description
Features:
High frequency and double conversion on-line technology

1.Wide input voltage range,True online UPS
2.Battery cold start .
3.DSP technology,advantaged battery management 
4.Automatical fan speed adjustment .Overload and short circuit protection
5. Large LCD status display, more information and history log
6.Complete protection functions 
7.Network/Fax/modem surge protections
8.EMI/RFI noise filter
9.Smart Rs232 port with monitoring software 
10. PFC technology
11.Intelligent slot for SNMP adaptor(optional)
12. Maintenance Bypass Switch(optional)


HT1106SHT1106LHT1110SHT1110LHT1115LHT1120L
INPUT





Cold StartYES, default frequency=50Hz or settableYES, default frequency=50Hz or settableYES, default frequency=50Hz or settableYES, default frequency=50Hz or settable
Acceptable Input Voltage50%~125%(220VAC/230VAC/240VAC)50%~125%(220VAC/230VAC/240VAC)50%~125%(220VAC/230VAC/240VAC)50%~125%(220VAC/230VAC/240VAC)

100% load@80%~125%100% load@80%~125%100% load@80%~125%100% load@80%~125%

90% load@70%~80%90% load@70%~80%90% load@70%~80%90% load@70%~80%

80% load@60%~70%80% load@60%~70%80% load@60%~70%80% load@60%~70%

65% load@50%~60%65% load@50%~60%65% load@50%~60%65% load@50%~60%
PhaseSingle phase in,single phase outSingle phase in,single phase outSingle phase in,single phase outSingle phase in,single phase out
Transfer Voltage Range  



    -Line low transfer110VAC/115VAC/120VAC110VAC/115VAC/120VAC110VAC/115VAC/120VAC110VAC/115VAC/120VAC
    -Line low recovery116VAC/122VAC/127VAC116VAC/122VAC/127VAC116VAC/122VAC/127VAC116VAC/122VAC/127VAC
    -Line high transfer275VAC/288VAC/300VAC275VAC/288VAC/300VAC275VAC/288VAC/300VAC275VAC/288VAC/300VAC
    -Line high recovery268VAC/279VAC/291VAC268VAC/279VAC/291VAC268VAC/279VAC/291VAC268VAC/279VAC/291VAC
Input Current



    -Rating(at nominal input voltage)32.5A51A76A102A
Input Power Factor≥0.99≥0.99≥0.95≥0.95
Input Frequency Range40Hz - 70Hz 40Hz - 70Hz 40Hz - 70Hz40Hz - 70Hz
GeneratorSupport Any GeneratorSupport Any GeneratorSupport Any GeneratorSupport Any Generator
OUTPUT




Frequency adaptableSettableSettableSettableSettable
Power



    -Power(kVA) max6101520
    -Power(kW) max5.4913.518
Output Voltage



    -WaveformPure sine wavePure sine wavePure sine wavePure sine wave
    -Nominal voltage220/230/240VAC220/230/240VAC220/230/240VAC220/230/240VAC
    -Voltage regulation± 1 %± 1 %± 1 %± 1 %
    -Transient response  ≤5% (50% - 100% -50%)≤5% (50% - 100% -50%)≤5% (50% - 100% -50%)≤5% (50% - 100% -50%)
    -Transient recovery≤15ms (0% - 100% -0%)≤15ms (0% - 100% -0%)≤15ms(0% - 100% -0%)≤15ms(0% - 100% -0%)
    -Voltage distortion≤1% THD, linear load        ≤1% THD, linear load ≤1% THD, linear load ≤1% THD, linear load 

≤5% THD, non-linear load≤5% THD, non-linear load ≤5% THD, non-linear load ≤5% THD, non-linear load 
Output Frequency



    -Synchronization rangesettable,±3Hz defaultsettable,±3Hz defaultsettable,±3Hz defaultsettable,±3Hz default
    -Slew rate0.5~5Hz/s,2 Hz/s default0.5~5Hz/s,2Hz/s default0.5~5Hz/s,2Hz/s default0.5~5Hz/s,2Hz/s default
    -Battery mode(50±0.05) Hz(50±0.05) Hz(50±0.05) Hz(50±0.05) Hz
Transfer Time



    -Line mode to battery mode0000
    -Inverter to bypass0.1ms000
Efficiency



    -Line mode with battery full charged93.0%93.0%93.0%93.0%
    -ECO mode98.0%98.0%98.0%98.0%
    -Battery mode92.0%92.0%92.0%92.0%
Noise<48dB@<70%load,<58dB@>70%load;1m away<48dB@<70%load,<60dB@>70%dB;1m away

Overload Capability (Line Mode)110%: Transfer to bypass after 60 mins.110%: Transfer to bypass after 60 mins110%: Transfer to bypass after 60 mins110%: Transfer to bypass after 60 mins
130%: Transfer to bypass after 1 min130%: Transfer to bypass after 1 min130%: Transfer to bypass after 1 min130%: Transfer to bypass after 1 min
150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)
Overload Capability (Battery Mode)110%: Shutdown after 10mins (Battery mode)110%: Shutdown after 10mins (Battery mode)110%: Shutdown after 10mins (Battery mode)110%: Shutdown after 10mins (Battery mode)
125%:Shutdown after 10s(Battery mode)125%:Shutdown after 10s(Battery mode)125%:Shutdown after 10s(Battery mode)125%:Shutdown after 10s(Battery mode)
>125%: Shutdown after 1s (Battery mode)>125%: Shutdown after 1s (Battery mode)>125%: Shutdown after 1s (Battery mode)>125%: Shutdown after 1s (Battery mode)
Crest Ratio3:13:13:13:1
BATTERY





Rating/Type12VDC/7AhDepend on the capacity of external batteries12VDC/9AhDepend on the capacity of external batteriesDepend on the capacity of external batteriesDepend on the capacity of external batteries
Quantity16161616
DC Voltage192VDC192VDC192VDC192VDC
Back-up Time4mins @80% loadDepend on the capacity of external batteries3.5mins @80% loadDepend on the capacity of external batteriesDepend on the capacity of external batteriesDepend on the capacity of external batteries
Battery-Low Voltage(176±3)VDC(176±3)VDC(176±3)VDC(176±3)VDC
Charger





    -Charging voltage(220±1%)VDC(220±1%)VDC(220±1%)VDC(220±1%)VDC
    -Charging current (max)1A5A1A5A5A5A
    -Charging time7h recharge to 90%Depend on the capacity of external batteries8h recharge to 90%Depend on the capacity of external batteriesDepend on the capacity of external batteriesDepend on the capacity of external batteries
Leakage current<1mA<1mA<1mA<1mA
INDICATOR & ALARM





DisplayLED+LCDLED+LCDLED+LCDLED+LCD
AlarmSounding once per secondSounding once per secondSounding once per secondSounding once per second
FaultContinuous beepingContinuous beepingContinuous beepingContinuous beeping
INTERFACE





Smart RS232Standard Cable support INVT Power Monitor SoftwareStandard Cable support INVT Power Monitor SoftwareStandard Cable support INVT Power Monitor SoftwareStandard Cable support INVT Power Monitor Software
Dry Contactor5 Ports5 Ports5 Ports5 Ports
SNMP(option)Power Managment from SNMP Manager and Web BrowserPower Managment from SNMP Manager and Web BrowserPower Managment from SNMP Manager and Web BrowserPower Managment from SNMP Manager and Web Browser
OPTION





ECO KitYESYESYESYESYESYES
Long Parallel CableYESYESYESYESYESYES
Parallel KitYESYESYESYESYESYES
SNMPYESYESYESYESYESYES
MECHANICAL





W*L*H (mm)250*526*480250*526*640250*526*480250*526*640250*544*750250*544*750
Net Weight (KG)571865203333
ColorBlackBlackBlackBlack
 