Guangdong, China
Business Type:
Manufacturer/Factory
Main Products:
UPS
Number of Employees:
385
Year of Establishment:
2010-07-12
Management System Certification:
ISO 9001
Average Lead Time:
Peak season lead time: within 15 workday
Off season lead time: within 15 workday
OEM/ODM Service

Rack Mount Ups, 19′′ 2u Ups, 19 2u Ups manufacturer / supplier in China, offering Hr11 Rack Mount UPS 1-10kVA 0.9pf, Invt Hr 1-10kVA 0.9pf Rak Mount UPS, Touch Screen Uninterruptible Power Supply 10-200K (HT33) and so on.

Gold Member Since 2011
Audited Supplier

Hr11 Rack Mount UPS 1-10kVA 0.9pf

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $1/ Piece
Transport Package: Carton
Payment Terms: L/C, T/T
Phase: Single Phase
Type: On-line
Protection: Overvoltage
Output Power Factor: >0.8
Output Voltage: 220V or 110V
Input Power Factor: >0.99

You Might Also Like

Loading...

Basic Info

Trademark: INVT
Specification: 1-6KVA
Origin: China
HS Code: 85044020

Product Description

HR series online rack mounted UPS 1-6kVA characteristics
1.19 inch rack mounted design.
2. Online double conversion technology.
3. IGBT PFC technology.
4. Wide input range.
5. Zero transfer time.
6. Compete protection function.
7. Advanced battery management.
8. Cold start.
9. Compete protection function.
10. Fan speed adjustment automatically.
11. Optional external battery bank.
12. EMI/RFI noise filter.
13. Shutdown and restart schedule.
Model HR111K HR112K HR113K HR116K
Rated Power
Power 1kVA/0.7kW 2kVA/1.4kW 3kVA/2.1kW 6kVA/4.2kW
Input
Nominal voltage 110VAC/220VAC 220VAC
Voltage range 60-138VAC/115-300VAC 176-276VAC
Frequency range 46-54Hz(default), user adjustable within 40-60Hz 46-54Hz
Power factor 0.97 0.98
Output
Voltage 110VAC/220VAC ± 2% 220VAC ± 1%
Frequency 50/60Hz± 0.2Hz 50/60Hz± 0.05Hz
Waveform Pure sine wave
Distortion Less than 2% under linear load
Overload capability 110%-150% for 30 seconds, 150% for 300 mS 105%-130% for 10min, 130% for 1min
Crest factor 3: 1
Battery
Type Internal External
Nominal DC voltage 36VDC 96VDC 240VDC
Bypass
Automatic transfer Overload time up and UPS failure
Transfer time 0mS
LCD/LED information and audible alarm
Status Load percentage, battery state, utility state, inverter and bypass state, overload, system fault.
Audible alarm Bypass mode, battery mode, battery low, overload, fault
Communications
DB9 port RS232
Intelligent slot WebPower, AS400 card and WinPower CMC
Environment
Operating temperature 0-40 0 C
Operating humidity 20-90 non-condensing
Weight
Net(kg) 15.3 10.3 11.2 18.3
Dimension
W*D*H(mm) 482*450*88(2U) 482*600*130(3U)

Send your message to this supplier

*From:
*To:
avatar Miss Sarah
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now