Basic Info.
Output Power Factor
0.8/1
Output Voltage
380V/400/415 or 200V/208V
Battery for UPS
Lead Acid Battery
UPS Type
60kVA UPS 60kVA Online UPS
Product Description
N+X Parallel Redundancy UPS 100kVA 80kVA
Application: ISP(Internet Service Provider), IDC(Internet Data Center), computing center, bank, server center, precise equipment and etc.
60kva for ISP IDC high frequency online ups
Features:
1. Three phase in and out system, compatible with utility of 380/400/415V, 50/60Hz
2. Online double conversion, offering load with best power quality
3. Support all kinds of load, high overload capability
4. Fully digital control with three DSPs including IGBT rectifier, inverter, charger
5. Digital circulating current control technology, increasing the parallel reliability
6. Wide input voltage window, compatible with different utilities
7. Green power technology, high input power factor, low current THD, high efficiency
8. Intelligent battery management, extending battery lifetime
9. Intelligent self-diagnose function, all kinds of fault protection, large capability of history record storage.
10. Full front maintenance, saving space.
11. Redundant design of power model fans, increasing the system reliability
12. Modularized design of subsystem, convenient field maintenance
13. High MTBF(mean time before failure)(>200, 000h), low MTTR(mean time to repair)(<0.5h)
14. Large LCD display, friendly human machine interface
15. Configured with top and bottom cable connection
16. Parallel up to 6 units.
17. All kinds of options include main back feed protection, bypass back feed protection, battery leakage protection, battery start kit, output isolation transformer and lighting protection kit.
Model | HT3310 | HT3315 | HT3320 | HT3330 | HT3340 | HT3360 | HT3380 | HT33100 | HT33120 | HT33160 | HT33200 |
Capacity | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA |
Main Input |
Input voltage | 380V/400V/415V(line to line), 50/60Hz |
Input connection | 3Ph+N+PE |
Power factor | >0.99 |
Input cuurent THD(Total Harmonic Distortion) | <3% |
Input voltage window | +20%~-20%, full load |
-20%~-40%, power derating between 100% to 70% |
Frequency window | 40-70HZ |
Bypass input |
Input voltage | 380V/400V/415V |
Input voltage window | +20%--20%, full load |
-20%--40%, power derating between 100% to 70% |
Frequency window | ±3Hz (adjustable) |
Battery |
Battery voltage | ±240VDC |
Charger power | 20%*Power |
Charger voltage precision | 1% |
Output |
Voltage precision | ±0.5% (balance load),2% (unbalance load) |
Output voltage transient | 2%(0~100% load step) |
Voltage THD(Total Harmonic Distortion) | THD<0.5%(linear load),THD<3%(nonlinear load) |
Power factor | 0.8 |
Frequency tracking range | 50/60Hz±3Hz, adjustable |
Frequency precision (free running) | ±0.01% |
Phase tolerance | 120°±0.5° (balance and unalance load) |
Voltage unbalance degree (100% unbalance load) | ±3% |
Frequency tracking speed | 0.5Hz/s to 5Hz/s, adjustable |
Crest factor | 3:1 |
Overload capabiltiy | 105% long time operation |
110%, transfer to bypass after 1hour |
125%, transfer to bypass after 10 minutes |
150%, transfer to bypass after 1 minute |
>150%, transfer to bypass after 200ms |
Bypass overload capability | 150%, long time operation |
150%< load <180%, last for more than 1 minute |
>1000%, last for more than 100ms |
System |
System efficiency | Normal mode: 95% |
ECO mode: 99% |
Battery mode efficiency | 95% |
Battery configuration | 12V, 40PCS (38~42pcs acceptable) |
Display | LCD+LED, Touch screen and keyboard |
EMI | IEC62040-2 |
EMS | IEC61000-4-2(ESD) |
IEC61000-4-3(RS) |
IEC61000-4-4 (EFT) |
IEC61000-4-5 (Surge) |
Insulation resistance | >2M (500VDC) |
Dielectric strengh | (input,output to PE)2820Vdc, leakage current lower than 3.5mA, no flashover in 1 minute |
Surge protection | Comply with IEC60664-1 class IV, endure surge of 1.2/50us + 8/20us higher than 6KV/3KA |
IP class | IP20 |
Interface (Communication Ports ) | RS232,RS485,Dry contacts,SNMP card,EPO,Generator interface |
Installation/Connection | Top or bottom cable connection |
Operation temperature | 0-40C |
Relative humidity | 0-90% (non-comdensing) |
Noise(dB) | <55dB |
Weight(KG) | 100 | 105 | 115 | 120 | 224 | 246 | 268 | 290 | 312 | 356 | 400 |
Dimension(W*D*H)(mm) | 520*690*1050 (Internal battery) | 600*900*1600 | 600*900*2000 |
Address:
1 # Building, Gaofa Industrial Park, Longjing, Nanshan District, Shenzhen, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001
Company Introduction:
As leading total power solution manufacturer in China, INVT POWER is committed to offer high quality products and service to global customers. The powerful R&D ability insures that products and solutions are the best choice for critical power applications.
The product lines cover modular UPS, high frequency UPS, low frequency UPS, EPS, inverter, telecom rectifier, battery. With our own complete intellectual properly rights, the power ranges from 0.5kVA to 800kVA. INVT owns advanced power supply technologies including DSP intelligent control system, fully digital parallel technique, fully IGBT technology UPS, advanced protection technique, etc.
INVT established the most powerful R&D platform for power supply development in China. The platform includes components lab, performance lab, mechanical environmental lab, climate environment lab, EMC lab and safety lab. Due to all of these technologies and platform, INVT products are considered to be the most advanced and reliable in China.